How the Math Works

See how radon levels become atom counts, decay rates, and inhaled-air estimates.

Defined conversion

From activity concentration to activity per liter

1 pCi/L = 37 Bq/m³ = 0.037 Bq/L

A becquerel is one nuclear decay per second. Because one cubic meter contains 1,000 liters, the activity per liter is the concentration in Bq/m³ divided by 1,000.

Radon-222 population

N = A ÷ λ

T½ = 3.8235 days = 330,350.4 secondsλ = ln(2) ÷ T½ ≈ 2.098 × 10⁻⁶ s⁻¹N = 0.037 Bq/L ÷ λ ≈ 17,635 radon-222 atoms/L at 1 pCi/L

Worked example: 1 pCi/L. The simulator starts at 4 pCi/L.

From atoms in air to atoms inhaled

  1. Radon atoms in air: N = A ÷ λ. N is atoms/L, A is activity in Bq/L, and λ is the decay constant shown above.
  2. Atoms inhaled per minute: atoms/L × breathing rate L/min.
  3. Cumulative atoms inhaled: atoms/min × minutes in the room.

Decays per minute in one liter = activity in Bq/L × 60.

Breathing-rate and time assumptions

The breathing-rate presets and activity multipliers are illustrative app assumptions, not validated EPA table values. EPA’s Exposure Factors Handbook provides age- and activity-specific reference data.

The age groups are broad illustrative categories, not defined age bands.

Calculations use your selected radon level and breathing rate for the time you spend in the room. For longer periods, you can adjust the number of hours spent in the room each day.

About the illustration

The lung animation illustrates how radon gas and its solid decay products interact with the respiratory system.

The calculated totals count atoms carried in inhaled air, not atoms retained in the lungs, radiation dose, or personal health risk.

The decay-chain diagrams show the main uranium-238 pathway; rare branches and gamma emissions are omitted.

Sources

Radon Visualizer
Educational Scope & Methodology

Radon Visualizer helps you explore radon science through interactive illustrations and calculations. It uses the radon level you enter to demonstrate scientific concepts. Only testing can determine the actual radon level in a building.

Study summaries distinguish published findings from our research team’s interpretations.

How the Math Works